This document contains Load and Resistance Factor Design (LRFD) criteria for hot-rolled, single-angle members with equal and unequal legs in tension, shear, compression, flexure, and for combined forces. It is intended to be compatible with, and a supplement to, the 1999 AISC Load and Resistance Factor Design Specification for Structural Steel Buildings and repeats some common criteria for ease of reference. For design purposes, the conservative simplifications and approximations in the Specification provisions for single angles are permitted to be refined through a more precise analysis. As an alternative to this Specification, the 1989 AISC Specification for Allowable Stress Design of Single-Angle Members is permitted.
The Specification for single-angle design supersedes any comparable but more general requirements of the AISC LRFD. All other design, fabrication, and erection provisions not directly covered by this document shall be in compliance with the AISC LRFD. For design of slender, cold-formed steel angles, the AISI LRFD Specification for the Design of Cold-Formed Steel Structural Members referenced in Section A6 of the AISC LRFD is applicable.