繁体】【设为首页】【收藏
当前位置:下载/Download首页 >> 工程规范 >> 欧标 >> BSEN1993-1-7-2007 Design of steel structures - Plated structures subject to
BSEN1993-1-7-2007 Design of steel structures - Plated structures subject to
  • 授权形式:
  • 作者/开发商:
  • 文件大小:未知
  • 软件语言:英文
  • 版本号:0
  • 软件平台:Windows/Unix/Linux/MacOS
  • 软件类别:
  • 点击次数:70
  • 评论等级:★★★☆☆
  • 更新时间:2008-07-31
  • 演示地址:
资源介绍:  
(1)P EN 1993-1-7 provides basic design rules for the structural design of unstiffened and stiffened plates which form part of plated structures such as silos, tanks or containers, that are loaded by out of plane actions. It is intended to be used in conjunction with EN 1993-1-1 and the relevant application standards.
(2) This document defines the design values of the resistances: the partial factor for resistances may be taken from National Annexes of the relevant application standards. Recommended values are given in the relevant application standards.
(3) This Standard is concerned with the requirements for design against the ultimate limit state of:
– plastic collapse;
– cyclic plasticity;
– buckling;
– fatigue.
(4) Overall equilibrium of the structure (sliding, uplifting, overturning) is not included in this Standard, but is treated in EN 1993-1-1. Special considerations for specific applications may be found in the relevant applications parts of EN 1993.
(5) The rules in this Standard refer to plate segments in plated structures which may be stiffened or unstiffened. These plate segments may be individual plates or parts of a plated structure. They are loaded by out of plane actions.
(6) For the verification of unstiffened and stiffened plated structures loaded only by in-plane effects see EN 1993-1-5. In EN 1993-1-7 rules for the interaction between the effects of inplane and out of plane loading are given.
(7) For the design rules for cold formed members and sheeting see EN 1993-1-3.
(8) The temperature range within which the rules of this Standard are allowed to be applied are defined in the relevant application parts of EN 1993.
(9) The rules in this Standard refer to structures constructed in compliance with the execution specification of EN 1090-2.
(10) Wind loading and bulk solids flow should be treated as quasi-static actions. For fatigue, the dynamic effects must be taken into account according to EN 1993-1-9. The stress resultants arising from the dynamic behaviour are treated in this part as quasi-static.
相关资源
声明
1. 本网支持版权保护。资源频道仅提供资源的介绍,以及部分不侵犯版权、内容合符本网协议要求的资源下载和预订;
2. 若本网页未显示资源下载或预订链接,表示本网不提供该资源的下载或预订;
3. 关于该资源的销售、技术、支持等详细情况,请进入作者/开发商的官方网站了解;
4. 资源频道的资源均由本网会员提供,如有问题请致Email给abuse@engrwebh.com投诉;
关于我们/About Us | 联系我们/Contact Us | 版权声明/Announce

  • ENGR网

    版权所有(c)2008-2010

  •